Rehabilitation of Head House and Tunnels at IFFCO Hamriya
- Installed Impressed Current Cathodic Protection (ICCP) to protect the reinforcing steel
- Installed Electro-Osmotic Pulse (EOP) system to prevent moisture ingress
Location
Project Team
IFFCO
Owner
STRUCTURAL
Specialty Contractor
STRUCTURAL TECHNOLOGIES
Material Supplier
Project Description
IFFCO is a UAE-based innovative and integrated multi food products Group. With an established global presence, the Group offers a wide range of food products, related derivatives, intermediates and services.
Condition Assessment
Based on the consultant’s assessment, heavy leakage and delamination was noted in the Head House especially in the lower basement and more excessively within the raft. The chloride level of the head house and tunnels indicates that the structure is at high risk of continuous corrosion of the reinforcement bars. Leakage and contaminants in the water causing delamination were mainly due to the fact that the facility is situated close to the seaport. Water ingress had disrupted the operations of the facility and this was further complicated by the presence of water-borne chloride ions which would surely lead to future interruptions with the continued degradation of the reinforcing steel in the concrete structure.
Faced with operational interference, there was an extensive requirement to stop water ingress and simultaneously protect the steel reinforcement from attack by the aggressive salts.
Repair Opportunity
STRUCTURAL won the project under the concept of installing STRUCTURAL TECHNOLOGIES’ Electro-Osmotic Pulse / Impressed Current Cathodic Protection (EOP/ICCP) throughout the structures. The combined technology will remove the existing moisture, prevent further water ingress and provide Cathodic Protection to selected elements of the Grain Store. With these systems, the coverage of areas that needed concrete repair can be reduced up to 25 percent as there is a much lesser need to remove all the initial rusting and scaling on the steel bars (where delamination and spalling are not yet present) given that further corrosion will already be halted.
The final scope of work included:
- Stopping the ingress of seawater through concrete walls
- Concrete remediation treatments to deal with delamination of concrete cover and steel corrosion, repairs and treatment of movement joints
- Non-structural crack injection
- Impressed Current Cathodic Protection (ICCP) to protect the reinforcing steel
- Electro-Osmotic Pulse (EOP) system to prevent moisture ingress